Cat 6, Cat 6A
or fibre to the desk
Cabling is the one part of a network you don't replace when it falls short: it sits inside the wall, the suspended ceiling or the trunking. That's why you don't choose it by the price per metre, but by how long your longest run is and by what you'll be asking of it in ten years: 10 gigabit, access points powered over PoE, cameras. Cat 6 is fine over short runs, Cat 6A covers everything up to 100 metres, and fibre comes in when distance or the environment rules copper out.
By Ismael Vázquez, founder and technician · Published 17 November 2026
It's not what a metre costs
It's how long your longest run is and what you'll plug into it ten years from now.
Cabling is the part of the network that stays. Switches, access points and computers get replaced every few years; the cable lives inside the wall, the suspended ceiling or the trunking, and replacing it later means opening all of that up again.
That's why the price difference between categories matters least. What decides it is the length of your longest run, whether you'll power devices over the same cable (cameras, access points, phones) and whether at some point you'll want more than 1 gigabit anywhere.
With those three answers, the choice almost makes itself.
What each option gives you
10 gigabit distances over copper from Fluke Networks' guide to 10GBASE-T; over fibre, from Cisco's datasheet for its 10 gigabit SFP+ modules.
| Cat 6 | Cat 6A | Fibre | |
|---|---|---|---|
| Specified frequency | 250 MHz | 500 MHz | Not applicable |
| 1 gigabit | Up to 100 m | Up to 100 m | Depends on fibre type |
| 10 gigabit | Up to 37 m; 37 to 55 m depending on interference | Up to 100 m | 300 m on OM3, 400 m on OM4, 10 km on single-mode |
| PoE | Yes, with less headroom in large bundles | Yes, recommended by TIA for new installations | Carries no power |
| Electrical interference | Affected | Less affected, even less if shielded | Unaffected |
| Where it fits | Short runs, no 10 gigabit plans | New office or shop installation | Between units, floors or distant cabinets |
Three questions that decide the category
You can answer them with a floor plan and a list of what you're going to connect.
How long is your longest run?
From the cabinet to the furthest point, along the route the cable will actually take, not in a straight line. With runs of a few tens of metres, Cat 6 handles 10 gigabit; beyond about 37 metres it's no longer guaranteed, and past 55 metres it isn't at all.
Will the cable carry power?
Cameras, Wi-Fi access points and phones are powered over PoE. The current heats the bundle, and Cat 6A, with its larger conductors, copes better: TIA's guidelines recommend it for new installations with PoE.
What will you ask of it in ten years?
Today an office desk runs at 1 gigabit with room to spare. Recent Wi-Fi access points, servers and links between switches are the first things to ask for more. If the answer is "I don't know", that's an argument for Cat 6A.
UTP or shielded
A shield protects if the whole installation is designed around it. If not, it just adds cost.
Unshielded (UTP)
The norm in offices, shops and practices. More flexible, easier to install and with no need for an earth connection at every outlet. In Cat 6A it covers 10 gigabit over 100 metres in an environment without strong interference.
Shielded
It has a foil or metal braid. Useful near machinery, motors, drives or heavy power lines. In return, connectors, outlets and patch panels must be shielded and the shield must be properly earthed; a badly connected shield doesn't protect.
Three cases for fibre
Not to the desk: between the points where copper falls short.
Between units or buildings
Copper gives you 100 metres per link. Between two units on one site or across an industrial estate, fibre covers hundreds of metres, and it carries no current from one building to the other.
Between floors or distant cabinets
The link between the main cabinet and the secondary ones carries the traffic of every workstation. It's the first run to need more than 10 gigabit, or more distance than copper can give.
Where there's heavy interference
Workshops, units with machinery, large switchboards. Fibre is unaffected by electrical noise, and on those runs it prevents intermittent faults that are hard to track down.
Cat 6A to the desk, fibre between cabinets
What we don't recommend: choosing cable by comparing the price of the reel.
In a new office or shop installation, Cat 6A to every desk: it reaches 10 gigabit over the full 100 metres, handles the PoE for cameras and Wi-Fi access points better, and doesn't force you to open walls when the devices change. Cat 6 is still reasonable in small premises with short runs and no plans to grow.
Fibre between cabinets, floors and units, and copper from each cabinet to the desks. Fibre to every desk only in very specific cases.
And always ask for the certification report for each outlet. On the structured cabling we install, we hand it over with the measurements, and it's what proves the installation meets the category printed on the jacket. Bear in mind, too, that the best internal cabling is no use if the line outside goes down: that's solved with backup internet.
If you're planning an office, a refurbishment or an industrial unit, we'll go over the floor plan with you and tell you which category makes sense on each run. It's part of how we deliver fibre & networks.
What people usually ask
What is the difference between Cat 6 and Cat 6A?+
Both are categories of twisted-pair cable for Ethernet networks, and from the outside they look very similar. The difference lies in the frequency they are specified for and in how they are protected against interference from neighbouring cables. According to Fluke Networks, Cat 6 is specified up to 250 MHz and Cat 6A up to 500 MHz. In practice that comes down to one thing: with Cat 6A you can carry 10 gigabits per second over 100 metres, the normal maximum length of a network link, whereas with Cat 6 that speed is only assured over considerably shorter runs. For 1 gigabit, which is what most computers use today, both reach 100 metres. Cat 6A is usually somewhat thicker and stiffer, which you notice when pulling it through narrow conduit.
How far does 10 gigabit go over Cat 6?+
Less than people tend to think. Fluke Networks' guide to the requirements of 10GBASE-T, the standard for 10 gigabit over copper, says it should work up to 37 metres of Cat 6, and between 37 and 55 metres depending on alien crosstalk, which is the interference cables induce in one another when they run together in the same bundle. Beyond 55 metres there is no guarantee. To cover the full 100 metres at 10 gigabit, the same manufacturer recommends Cat 6A. If your installation has short runs, for example a small office with the cabinet in the middle, Cat 6 may be enough; if there are long runs, don't take it for granted without testing.
Do I need 10 gigabit in an office?+
Today, at most desks, no: an ordinary office computer works at 1 gigabit and doesn't notice. The useful question is a different one: what are you going to plug into that cable over the coming years? Recent Wi-Fi access points, servers, storage arrays and links between switches are the first things to ask for more than 1 gigabit. Cable stays in the wall far longer than the devices plugged into it, and replacing it later means opening up trunking and suspended ceilings again. That's why, in a new installation, it makes more sense to think about what you'll need in ten years than about what you connect on day one.
What does PoE have to do with cable category?+
PoE carries power over the same cable as the data, and that current heats the cable, especially when many PoE cables run together in a bundle. TIA's guidelines for powering devices over network cable, bulletin TSB-184-A, recommend Cat 6A or higher for new installations that will deliver power. Fluke Networks sums it up like this: to stay within a 15 °C temperature rise with 100 W PoE, those guidelines allow about 25% more unshielded Cat 6A cables in a bundle than Cat 6, thanks to their larger conductor size. If you're going to power cameras, access points or phones from the cabinet, that's one more argument for Cat 6A.
Shielded or unshielded cable?+
It depends on the environment. Unshielded cable, UTP, is the most common choice in offices and shops, and in Cat 6A it more than does the job. Shielded cable has a foil or metal braid that protects against external interference and crosstalk between cables, and is useful near machinery, drives, motors or heavy power lines. The catch is that the shield only works if the installation is consistent from end to end: shielded connectors, outlets and patch panels, and a proper earth connection. A badly connected shield doesn't protect, and can cause more trouble than having none. In a normal office, well-installed UTP; in a unit with machinery, shielded cable is worth considering, or fibre outright on the most exposed runs.
When should you use fibre instead of copper?+
When the distance exceeds what copper can deliver, or when the environment advises against it. Copper network cable has a limit of 100 metres per link, so between two units on the same site, between distant floors or on long runs across an industrial estate, fibre is the norm. For reference, Cisco's datasheet for its 10 gigabit modules gives 300 metres over OM3 multimode fibre, 400 over OM4 and 10 kilometres over single-mode. Fibre is also unaffected by electrical interference, which makes it attractive near machinery, and it carries no current between buildings. What's usual in a business is not fibre to every desk, but fibre between cabinets and copper from each cabinet to the workstations.
Is fibre to every desk worth it?+
In most offices and shops, no. Computers, printers, phones and cameras have copper ports, and Wi-Fi access points and cameras are powered over PoE, which only runs over copper. Taking fibre to the desk means fitting converters or dedicated cards at each workstation and giving up PoE. It makes sense in specific cases: desks very far from the cabinet, environments with heavy electrical interference, or speed requirements well above the usual. For everything else, Cat 6A to the desk and fibre between cabinets covers whatever can be foreseen today.
How do I know whether the cable being installed meets the category?+
Ask for certification. The reel saying Cat 6A doesn't guarantee the finished link is: a badly crimped connector, too tight a bend radius or a makeshift joint brings down the performance of the whole run. The way to check is to test every outlet with a cable certifier, which compares the link against the parameters the standard requires for that category and produces a report. That report is what lets you make a claim if something fails, and what shows, years later, what you actually have in the wall. If an installer doesn't hand it over, all you know about the cable is what's printed on the jacket.
Let’s take the step together
Shall we look at it
together?
Tell us about your situation and we'll give you just the advice you need, without overselling. Free quote. We take calls in Spanish or Catalan; in English we reply by email or WhatsApp.
644 836 122CALL OR WHATSAPP USAsk for advice and a quote
Fill this in and we'll call you. No obligation.